CC-Link IE Safety Communication Function
A safety communication function realized on each network of CC-Link IE
CC-Link IE Safety realizes safety communication functions while utilizing the features of each CC-Link IE network. With CC-Link IE Safety, safe control can be mixed in the system of general control and motion control.
CC-Link IE Safety Communication Function Features
A safety communication function realized on each network of CC-Link IE
- With the high-speed of each CC-Link IE network, a safety system with high responsibility can be constructed.
Achieves a mixture of safety control in general control and motion control
- Safety control system can be introduced into general control and motion control system.
Based on an international standard of the safe communication
- CC-Link IE safety communication satisfies the requirements necessary for SIL3 compliance, which are indicated in IEC 61508.
Safe control and general control can be mixed
The CC-Link IE system that implements safety communication comprises CC-Link IE stations (IE safety stations) equipped with safety communication functions and CC-Link IE stations (IE standard stations) not equipped with safety communication functions. Fig. 1 shows an example of a configuration.
Compatible standards
Table 1 shows the international safety standards corresponding to CC-Link IE safety communication. CC-Link safety communication satisfies the requirements necessary for SIL3 compliance, which are indicated in IEC 61508. In addition, CC-Link IE safety communication follows the basic concept of functional safety communication defined in IEC 61784-3.
Standard No. | Name | Safety Level |
---|---|---|
IEC61508:2010 | Functional safety standards for electrical/electronic/programmable electronic safety-related systems | SIL3 |
IEC61784-3:2010 | Industrial communication networks – Profiles – Part 3: Functional safety fieldbuses | - |
Safety station internal
A safety stations connected to CC-Link IE Safety has IE safety communication layer. IE safety communication layer has one or more IESMAP (Master) and/or one or more IESSLP (Device). IESMAP is a protocol machine establishing a safety connection with the IESSLP specified as its safety parameter and performing safety communication with the IESSLP. IESMAP always invokes a safety connection establishing process.
IESSLP is a protocol machine establishing a safety connection with the IESMAP sending a connection request from, and performing safety communication with the IESMAP.
IESMAP (IE Safety Master Protocol Machine)
protocol machine establishing a safety connection with the IESSLP specified as its safety parameter after sending a connection request to the IESSLP; receiving a response from it; and confirming its identification, and performing safety communication with the IESSLP
IESSLP (IE Safety Device Protocol Machine)
protocol machine establishing a safety connection with the IESMAP sending a connection request from, and performing safety communication with the IESMAP
Specification
Item | Specification |
---|---|
Communication method | Connection type |
Max number of stations | CC-Link IE controller network: 120 CC-Link IE field network: 254 |
Max number of safety connection for same stations | 2 |
Max number of links of safety refresh | ingress 16 octets / egress 16 octets |
Safety Integrity Level (IEC61508) | SIL3 |